101
Table 17. Estimated Cost Effectiveness for Potential Control Measures
Average Cost effectiveness ($/ton)
Emission category Control strategy Region SO2 NOX NH3
EGU EGU1 3-State 1,540 2,037
9-State 1,743 1,782
EGU2 3-State 1,775 3,016
9-State 1,952 2,984
ICI boilers ICI1 3-State 2,992 2,537
9-State 2,275 1,899
ICI Workgroup 3-State 2,731 3,814
9-State 2,743 2,311
Reciprocating engines 3-State 538
emitting 100 tons/year or
more 9-State 506
Reciprocating engines
and turbines
Turbines emitting 100 3-State 754
tons/year or more 9-State 754
Reciprocating engines 3-State 1,286
emitting 10 tons/year or more 9-State 1,023
Turbines emitting 10 3-State 800
tons/year or more 9-State 819
Agricultural sources 10% reduction 3-State 31 - 2,700
9-State 31 - 2,700
15% reduction 3-State 31 - 2,700
9-State 31 - 2,700
Mobile sources Low-NOX Reflash 3-State 241
9-State 241
MCDI 3-State 10,697
9-State 2,408
Anti-Idling 3-State (430) - 1,700
9-State (430) - 1,700
Cetane Additive Program 3-State 4,119
9-State 4,119
Cement Plants Process Modification Michigan -
Conversion to dry kiln Michigan 9,848
LoTox™ Michigan 1,399
Glass Manufacturing LNB Wisconsin 1,041
Oxy-firing Wisconsin 2,833
Electric boost Wisconsin 3,426
SCR Wisconsin 1,054
SNCR Wisconsin 1,094
Lime Manufacturing Mid-kiln firing Wisconsin 688
LNB Wisconsin 837
SNCR Wisconsin 1,210
SCR Wisconsin 5,037
FGD Wisconsin 128 - 4,828
Oil Refinery LNB Wisconsin 3,288
SNCR Wisconsin 4,260
SCR Wisconsin 17,997
LNB+FGR Wisconsin 4,768
ULNB Wisconsin 2,242
FGD Wisconsin 1,078